Pressure levels
Predefined pressure level sets
With the parameter MET_PRESS_LEVEL_DEF
vertical pressure levels can
be selected from a number of definitions. The definitions follow the
ECMWF's model level definitions.
Additional levels up to ~1045 hPa have been added to avoid
extrapolation errors near the surface. Per default, the value is set
to -1 and hence pre-defined pressure level sets ignored. The
recommended pressure level set for ERA5 is number 6.
MET_PRESS_LEVEL_DEF | Name | bottom | top | number of levels |
---|---|---|---|---|
0 | L137 | 1044.45 hPa | 0.02 hPa | 138 |
1 | L91 | 1044.45 hPa | 0.02 hPa | 92 |
2 | L60 | 1044.45 hPa | 0.01 hPa | 60 |
3 | L137 | 1044.45 hPa | 0.02 hPa | 147 |
4 | L91 | 1044.45 hPa | 0.02 hPa | 101 |
5 | L60 | 1044.45 hPa | 0.01 hPa | 62 |
6 | L137 | 1044.45 hPa | 0.01 hPa | 137 |
7 | L60 | 1046.13 hPa | 0.1 hPa | 59 |